TR40 --- 40W CO2 Laser Tube With Red Pointer
TR40 --- 40W CO2 Laser Tube With Red Pointer
SPT laser is the first manufacturer in the world to develop and produce coaxial red light indicating CO2 laser tube. The red light module is designed as a separate 5V DC power supply. It can also obtain power from the existing laser power supply or control card. During laser lens correction, the laser transmission path can be accurately visualised, which makes the adjustment of the optical path more precise, convenient, and safe thanks to its red light preview and positioning functions.
SPT- TR40 Main Parameters:
Model: TR40 |
Rated power: 40W |
Wavelength: 10.6μm |
Excitation mode: Electrical excitation |
Length: 830±5mm |
Max. power: 50W |
Diameter: 80±1mm |
Power stability: ≤±5% |
Strating voltage: 5mA |
Strating voltage: 17kV |
Working voltage: 10kV |
Spot diameter: 4±1mm |
Recommended current: 18mA |
Maxmun working current: ≤25mA |
Beam divergence angle: 3.1mrad |
Beam quality: ≤1.1 |
Cooling: Water-cooled 15-25℃ |
Laser mode: Multi-low-order mode |
Modulated frequency: ≤3kHz |
Carton package: 940*173*155mm |
Net weight: 1.76kg | Gross weight: 2.74kg |
Laser tube Insufficient carving depth:
If at the beginning the carving is not deep, please check the following problems in order:
1. Check if the bearing of the co2 laser tube is appropriate;
2. Check if the light intensity is set too low;
3. Check if the light path has shifted;
4. Check if the focal distance is correct;
5. Check if there are any scratches and dirt on the surface of the lens;
6. Check if the flow rate and pressure of the cooling water are correct.
After working for a while, cutting depth is not deep enough anymore:
1. Check if the bearing of the co2 laser tube is appropriate;
2. Check if the water temperature normal;
3. Check if the lens gets hot when it is being used;
4. Check if the flow rate and pressure of the cooling water is correct;
5. Check if the cooling water is clean;
High voltage ignition and discharge:
1. Check for dirt or dampness around the high-pressure head of the laser tube;
2. Check if the high-pressure end or joint are too close to the metal part of the machine;
3. Check if the laser power supply high-voltage connection device is detached from the support;
4. Check if the high-voltage connection device is broken or damaged;
5. Check if the low water temperature leads to water condensation in the tube’s walls and sleeves;
* If none of the above descriptions apply, please contact our company’s after-sales service for consultation and treatment.
Laser tube broken:
1. Low water temperature leads to water freezing inside the glass laser tube;
2. There is no water in the laser tube;
3. Water pressure is too low;
4. Check if the direction of the water flow complies with low input and high output. The water-cooled tube of the laser tube may not be filled with water, and causing partial heating of the co2 laser tube.
High voltage discharge and breakdown:
1. The laser power supply does not work with different specifications (such as using a high-power supply for low-power laser tubes). Exceeding the specified voltage that the laser tube can withstand leads to damage of the co2 laser tube.;
2. The water cooling condition is not good. The cooling water does not fill the whole pipe and air bubbles appear. At the places where there is no water cooling, the temperature is too high, causing glass material to change and damaging to the glass of the co2 laser tubes;
3. The glass material has tiny bubbles or uneven thickness due to the influence of temperature, raw material, technology and other factors during the production of glass material. Damage to the weak areas under high voltage can cause discharge;
Fault detection instructions for using laser power supply:
The following detection methods apply when the co2 laser tube is not externally damaged
1. If the laser power supply has a wear detection function, then when the laser is in a standby state, press the test switch to turn on the laser’s lights and there will be a laser output from the laser tube. If the light does not turn on, then there is a laser power supply failure; If the lights turn on, but there is no laser output, then the laser tube is broken.
2. If the laser power supply does not have wear detection functions, the signal ports 5V and IN of the laser power supply are connected by wires; the three ports of L, P, and G are connected. When the laser power supply is turned on and the current is over 10 mA, if there is no laser output or if the laser energy output is weak, it means that the co2 laser tube is damaged. If the current is below 10 mA, then the laser power supply is broken.
Related Search